Product Knowledge

Coaxial Cable Stripping Machine and FAKRA Crimping Guide

Under mainstream automotive FAKRA specifications published by connector manufacturers such as Rosenberger, standard 50 Ω FAKRA interfaces operate from DC up to 6 GHz with return loss ≥18 dB across -40 °C to +105 °C, and stamped-and-formed FAKRA terminals are supplied on coils specifically for automated harness processing.

Holding those RF and mechanical tolerances at production speed comes down to three tightly coupled process steps: rotary coaxial cable stripping, uniform braid brushing, and servo-monitored FAKRA crimping. A minor blade nick on the center conductor, stray braid wire, or unmonitored crimp-height shift can degrade high-frequency impedance before the finished harness ever reaches electrical test.

This guide focuses specifically on how the stripping, braid-loosening, and dual-servo crimping stations inside MIJOINT’s Fully Automatic FAKRA Wire Harness Assembly & Inspection Line control those exact failure points. For full-line dimensions, UPH specs, MES architecture, and 6-step project planning, see our Comprehensive Guide to FAKRA Wire Harness Assembly and Inspection Equipment.

1. Why Coax Wire Stripping & Termination Fail Under Conventional Methods

Unlike single-core automotive leads, coaxial cables combine four concentric layers—outer jacket, braided metal shield, dielectric insulator, and center conductor. Conventional straight-blade strippers and unmonitored mechanical presses introduce recurring process risks:

Processing Stage Common Manual / Conventional Risk Impact on Automotive FAKRA Harnesses Automated Station Control
Jacket & Dielectric Stripping Straight blades crush soft dielectric or nick center conductor / shield braid Impedance discontinuity, return-loss degradation, broken strands 3-blade concentric rotary cold stripping with servo blade depth & eccentricity compensation
Shield Braid Handling Uneven manual folding or frayed copper strands Outer-ferrule jamming, stray-strand short circuits, inconsistent shield grounding Universal X/Y/Z multi-axis flexible braid-loosening mechanism
Center-Pin & Ferrule Crimping Unmonitored press stroke variation Missing strands, poor compression, hidden loose crimps passing visual check Dual-servo silent crimping (±0.01 mm) + real-time force-displacement curve monitoring

2. Three-Blade Concentric Rotary Coaxial Cable Stripping Machine

To eliminate blade-induced conductor damage during coax wire stripping, MIJOINT integrates a three-blade concentric rotary coaxial cable stripping machine module engineered for multi-layer automotive RF cables:

  • Three-blade synchronous concentric cutting: Three blades orbit the cable concentrically with high stability and zero radial wobble, cleanly slicing tough outer jackets and dielectrics without tearing the braid.
  • 1–4-layer stepped cold stripping: Removes outer jacket, shielding layer, dielectric insulation, and inner conductor exposure sequentially with flat, burr-free cut faces.
  • Servo blade depth & eccentricity compensation: Achieves strip-length accuracy of ≤±0.1 mm while servo-driven auto-centering compensates for cable eccentricity, preventing nicks on the center conductor or shielding mesh.
  • Multi-cable recipe adaptability: Configured for RG174, RG316, and other automotive coaxial cables based on each customer’s cable construction and stepped strip drawing.

3. Universal Multi-Axis Braid Brushing & Shield Flaring

Even a perfect rotary strip can fail at outer-ferrule assembly if the braided shield is compressed unevenly or left frayed. MIJOINT follows stripping with a dedicated universal braid-loosening station:

  • X/Y/Z multi-angle deflection + rotary oscillation: Combines variable-frequency drive control with an eccentric oscillating mechanism to open and flare the braided shield uniformly around the circumference.
  • Non-damaging flexible action: Contacts only the shielding braid, avoiding scratches on the inner dielectric or stress on the center conductor.
  • Programmable process recipes: Loosening depth, oscillation amplitude, rotation speed, and clamping force are all set digitally so every harness enters FAKRA crimping with repeatable shield geometry.

4. Dual-Servo FAKRA Crimping & Crimp Force Monitoring

Once the cable layers are stripped and the braid is evenly flared, termination quality depends on both mechanical press precision and real-time process verification.

Programmable Dual-Servo Silent Crimping

MIJOINT’s dual-servo direct-drive silent crimping press handles both center-pin and outer-conductor crimping with low mechanical impact:

  • ±0.01 mm crimping accuracy: Direct-drive servo positioning delivers high repeatability across long production runs to support stable RF impedance.
  • Full touchscreen parameter control: Crimping height, stroke, upper pressure limit, speed, and dwell time are programmed directly on the HMI, cutting mechanical readjustment time during changeovers.

Real-Time Crimp Force Monitoring

Integrated crimp force monitoring captures the complete pressure-displacement curve for every single crimp stroke:

  • Immediate hidden-defect detection: Flags poor crimping, missing wire, and missing core/strands as soon as a live waveform deviates from the reference tolerance window.
  • Closed-loop sorting & traceability: Pairs directly with inline vision (verifying stripping dimensions, exposed inner conductor, and assembly seating) and electrical testing (continuity, short, open, insulation resistance) so nonconforming parts are rejected automatically and crimp curves are archived to MES.

Dealing with nicked center conductors, stray braid shorts, or crimp-height drift on an existing coaxial line? Send your cable specification and FAKRA connector drawing to MIJOINT’s engineering team for a station-level process evaluation.

5. Process Control Benchmarks at a Glance

Core Process Station Key Engineering Mechanism Controlled Tolerance / Verification Scope
Rotary Coaxial Stripping 3-blade concentric cold cutting + servo depth + auto-centering 1–4 layers; strip-length accuracy ≤±0.1 mm; zero nicking on core/braid
Braid Loosening Universal X/Y/Z flexible oscillation + VFD speed control Uniform shield flare; programmable depth, amplitude, speed & clamp force
Dual-Servo Crimping Direct-drive silent servo press + HMI recipe control ±0.01 mm crimping accuracy (center pin & outer conductor)
Crimp Force Monitoring Live pressure-displacement curve analysis Detects poor crimping, missing wire, missing core; curve stored to MES
Downstream Verification Inline vision + electrical test + auto NG rejection Strip size, exposed conductor, seating + continuity, short, open, insulation

For complete machine specifications, cycle time (≤6 s per double-ended harness / up to 1,200 terminated ends per hour), 10-minute modular changeover, and project planning inputs, explore our Fully Automatic FAKRA Wire Harness Assembly & Inspection Line or read which FAKRA cable assembly steps can be automated.

Frequently Asked Questions

1. Why is a 3-blade concentric rotary coaxial cable stripping machine better than straight blades for FAKRA cables?

Straight blades apply asymmetric clamping force that can flatten soft coaxial dielectrics or score thin center conductors. Three concentric rotary blades with servo depth control and eccentricity compensation remove 1–4 layers cleanly within ≤±0.1 mm without damaging the shielding braid or inner conductor.

2. How does universal braid loosening prevent short circuits during FAKRA crimping?

By using programmable X/Y/Z flexible oscillation rather than rigid brushes or manual folding, the station spreads the braided shield evenly without scratching the dielectric. Uniform flaring prevents loose copper strands from folding inward toward the center pin when the outer ferrule is assembled and crimped.

3. What defects can crimp force monitoring catch that vision inspection cannot see?

Once a FAKRA center pin or outer ferrule is closed, internal conductor compression is hidden from cameras. Real-time crimp force monitoring compares every stroke’s pressure-displacement waveform against programmed tolerances to catch missing wire, missing core strands, or under-crimped terminals immediately.

4. Can one rotary stripping and servo crimping line handle different coaxial cable types like RG174 and RG316?

Yes. Because blade depth, strip lengths, braid-loosening parameters, and dual-servo crimping strokes are all stored as touchscreen recipes, MIJOINT’s modular line accommodates RG174, RG316, and other automotive coaxial cable specifications with changeover within 10 minutes.

Reference: Automotive FAKRA interface specifications (50 Ω impedance, DC–6 GHz, ≥18 dB return loss, -40 °C to +105 °C) are cited from Rosenberger FAKRA product documentation for industry context; station capabilities reflect MIJOINT’s Fully Automatic FAKRA Wire Harness Assembly & Inspection Line.